RT dose & DVH

Read an RT Dose grid, sample the dose at points, compute a dose-volume histogram against an RT Structure Set, rasterise an ROI to a mask, and author an RT Dose file. Quantitative geometry and coverage checks run in the shared native RT engine; IOD conformance remains available through the shared validator.

Read a dose grid

import pydcm

grid = pydcm.read_rtdose("rtdose.dcm")
grid.dose            # 3-D float array, real-world dose (Gy)
grid.affine          # 4x4 voxel->world
grid.spacing         # (z, y, x) mm
grid.frame_offsets_mm  # authoritative double-precision frame offsets
grid.origin_lps, grid.column_step_lps, grid.row_step_lps
grid.max_dose, grid.dose_units, grid.dose_summation_type

For one-frame or nonuniform dose grids, has_uniform_affine is false and no fake z step is inserted into affine; use frame_offsets_mm for resampling or round-trip writing. Stored DVHs retain all ROI INCLUDE/EXCLUDE relationships, volume units and optional statistics. A malformed optional stored DVH is reported by stored_dvh_error without hiding an otherwise usable dose grid.

Point dose

dose_at reads the dose at arbitrary patient coordinates — what a prescription point or a measured location received, rather than what a structure received.

values, inside = pydcm.dose_at("rtdose.dcm", points)   # points: (N, 3)

points is (N, 3) patient coordinates in the dose object's own Frame of Reference (a single (3,) point is accepted too). values is (N,) Gy and inside is (N,) bool. Interpolation is trilinear.

The inside flag is what a bare number cannot say: a point the grid does not cover comes back with inside=False and a value of 0, while a point where the dose genuinely is zero comes back with inside=True. They are the same number and mean opposite things, so filter on the flag before trusting a zero:

covered = values[inside]        # drop the off-grid points

Points measured in another Frame of Reference must be transformed first — nothing here treats a mismatched frame as identity, because that would sample the right grid at the wrong place and report a plausible number:

reg = pydcm.read_registration("reg.dcm")
xform = reg.transform(source_for, grid.frame_of_reference_uid)   # (4, 4)
pts_in_dose_frame = points @ xform[:3, :3].T + xform[:3, 3]
values, inside = pydcm.dose_at("rtdose.dcm", pts_in_dose_frame)

Compute a DVH

dvh = pydcm.dvhcalc("rtstruct.dcm", "rtdose.dcm", roi_number)
dvh.volume                  # cm3
dvh.min, dvh.mean, dvh.max  # Gy
dvh.counts                  # per-bin differential histogram
dvh.cumulative              # cumulative DVH
dvh.bins                    # bin edges (Gy), len(counts)+1

dvhcalc uses the engine's fixed base policy: fractional contour coverage, patient-space dose interpolation and compensated histogram/statistics. limit truncates the returned histogram in cGy without truncating full-volume integration or dose statistics.

samples_per_axis (1..32) sets the fractional-coverage sampling density — a higher value trades speed for a finer partial-pixel estimate; the default is the engine's. require_full_dose_coverage=True refuses a structure the dose grid does not fully reach, rather than reporting it with a coverage note:

dvh = pydcm.dvhcalc("rtstruct.dcm", "rtdose.dcm", roi_number,
                    samples_per_axis=16, require_full_dose_coverage=False)

When the grid does not cover the whole structure, the volume splits: dvh.volume is the total ROI (with the default calculate_full_volume=True), while dvh.covered_volume and dvh.uncovered_volume are the part the dose grid actually produced a histogram for, and dvh.notes says so. Per-cent readings are of the covered volume, because that is what the histogram is of.

Read dose constraints

The D(V) / V(D) readings come from the engine's own bin search — the same grammar the DVH constraint parser accepts — so a constraint reads the same here, in the CLI and in a viewer. The common ones are plain attributes:

dvh.D95      # dose 95% of the volume receives (Gy)
dvh.D2cc     # dose the hottest 2 cm3 receives (Gy)
dvh.V20Gy    # volume receiving at least 20 Gy (cm3)

Each is a DVHValue: it compares and formats as its number — dvh.D95 > 60, f"{dvh.D95:.1f}", float(dvh.D2cc) — while its repr keeps the units visible. A reading with no answer (the structure is smaller than the volume asked about) is NaN, never a misleading 0.

Names that are not valid Python attributes — the % forms — go through statistic:

dvh.statistic("V100%")   # volume receiving at least 100% of the prescription
dvh.statistic("D0.5cc")  # dose the hottest 0.5 cm3 receives

Or spell the two readings out directly, choosing the units:

dvh.dose_constraint(95)          # D95  — volume as a % (the default)
dvh.dose_constraint(2, "cc")     # D2cc — volume in cm3 ("cc" or "cm3")

dvh.volume_constraint(20)        # V20Gy — dose in Gy (the default)
dvh.volume_constraint(2000, "cGy")
dvh.volume_constraint(100, "%")  # a % of rx_dose (needs a prescription)

The % forms need a prescription. Set rx_dose in Gy, or hand dvhcalc an RT Plan (or a path to one) to read it from the plan's largest target prescription:

dvh = pydcm.dvhcalc("rtstruct.dcm", "rtdose.dcm", roi_number, rx_dose="rtplan.dcm")
dvh.statistic("V95%")            # 95% of the plan's prescription

describe() prints the constraints a plan review reads first (volume, the covered/uncovered split, min/mean/max, D100…D2cc, and the % volumes when a prescription is set) and returns them as a dict:

report = dvh.describe()

RTSTRUCT ROI to a mask

roi_mask rasterises one ROI of an RT Structure Set to a boolean volume on a reference image series' grid:

mask, meta = pydcm.rt.roi_mask("rtstruct.dcm", reference_series, roi_number)
mask.shape            # (planes, rows, cols) bool — one plane per reference slice
meta["roi_name"]
meta["set_voxels"]    # how many voxels the ROI set
meta["findings"]      # what the mask could not simply state (see below)

reference_series is the image series the mask should land on — a directory, a file, or a list of instance paths. Its slices are the target planes in the same order the authoring writers use, so a mask and a Segmentation authored from the same series share one grid. roi_number is the ROI Number (the identifier dvhcalc also takes), one ROI per call. A pixel is in when its centre is.

When the structure set and the reference series live in different Frames of Reference, pass the fusion transform; omitting it there is refused rather than treated as identity:

reg = pydcm.read_registration("reg.dcm")
xform = reg.transform(struct_for, series_for)             # (4, 4) RTSTRUCT->series
mask, meta = pydcm.rt.roi_mask("rtstruct.dcm", reference_series, roi_number,
                               transform=xform)

meta["findings"] explains any placement the mask cannot state on its own — contour_on_no_plane (a contour reaches past the series), same_plane_nested (nested CLOSED_PLANAR contours unioned, since the standard defines no hole for them), same_plane_partial_overlap, and others. Each is reported rather than silently applied.

For how a registration composes two Frames of Reference — and where struct_for and series_for come from — see the spatial-registration how-to.

Author an RT Dose

Typical use: a predicted or accumulated dose grid → a file a TPS or viewer can import.

pydcm.write_rtdose(
    dose,                       # 3-D float array (Gy)
    affine=grid.affine,         # voxel→world (read_rtdose / load_series convention)
    grid_frame_offsets=grid.frame_offsets_mm,  # preserves nonuniform geometry
    dose_units="GY",
    dose_summation_type="PLAN",
    output="dose_out.dcm",
)

Pass geometry as affine, or as origin + orientation + spacing. Omit output to get Part-10 bytes. The export quantises to integers with a self-consistent DoseGridScaling. For PLAN/BEAM-style summation, also pass an RT Plan reference (or ref_plan_uid) when a conformant relationship is required.