Diffusion tensor imaging (DTI)

pydcm.dti estimates the diffusion tensor from a DWI series and turns it into the usual scalar maps — FA, MD, AD, RD, a directionally-encoded colour map — and into deterministic streamlines. The tensor fit and the tracking run in the native engine; this is a thin NumPy surface that orchestrates the series, splits the baselines, and refuses a couple of inputs the engine cannot tell are wrong.

Units follow the b-values: with b in s/mm², the diffusivities (MD, AD, RD) are mm²/s and FA is dimensionless. Streamline coordinates are millimetres — patient mm from track_series, and patient mm are what any DICOM output needs.

Fit a series

fit_series reads a DWI directory, separates the b=0 baselines from the diffusion directions using the series' own Manufacturer, fits the tensor, and returns the maps with the geometry attached:

from pydcm import dti

res = dti.fit_series("ep2d_diff/")     # default maps ("FA", "MD")
res["FA"], res["MD"]                    # (Z, Y, X) float32
res.affine                             # voxel -> patient, row-major 4x4
res.spacing                            # (col, row, slice) mm
res.shape                              # (depth, rows, cols)

res is a dict of {map name: array} with the grid carried alongside — a map cannot be written or tracked without its affine, so it travels with the maps. Ask for more maps by name:

res = dti.fit_series("ep2d_diff/",
                     maps=("FA", "MD", "AD", "RD", "DEC", "CL", "CP", "CS"))
res["DEC"]                             # (Z, Y, X, 4) uint8 RGBA colour map

Every map name the engine accepts:

name shape / dtype what it is
FA float32 fractional anisotropy
MD float32 mean diffusivity (mm²/s)
AD float32 axial diffusivity, λ₁ (mm²/s)
RD float32 radial diffusivity, (λ₂+λ₃)/2 (mm²/s)
DEC uint8 RGBA direction-encoded colour, principal axis × FA
CL CP CS float32 Westin-1997 linearity / planarity / sphericity (÷λ₁)
linearity planarity sphericity float32 the trace-normalised form of the same three

Pass wls=True to weight the fit by signal² instead of ordinary least squares.

Masking — why an unmasked FA map peaks in air

Outside the head the signal is noise. The log-linear fit is degenerate there, and the eigen decomposition returns an arbitrary direction with FA near 1 — so an unmasked FA map has its maximum in the background, and a histogram over the whole volume describes mostly air. fit_series returns the fit as measured by default (mask=False); pass mask=True to zero the maps outside a head mask:

res = dti.fit_series("ep2d_diff/", mask=True)   # or mask=your_uint8_array
res["FA"].max()                                  # now inside the head, not in air

mask=True builds the mask from the mean baseline; you can also pass your own (Z, Y, X) array. head_mask is the same routine, exposed directly for inspection or reuse:

mask, kept = dti.head_mask(b0)        # b0: 3-D (Z, Y, X) baseline; mask uint8, kept voxels

It median-filters, thresholds with Otsu, and dilates. cleanup=True additionally removes islands and fills pockets — better for seeding, but a departure from the reference behaviour it was matched against.

Tractography

track_series fits the tensor and traces deterministic RK4 streamlines, returning them in patient coordinates:

tracks = dti.track_series("ep2d_diff/")   # list of (P, 3) float64 arrays, patient mm

Tracking applies a head mask before seeding by default, for the same reason the FA map needs one — an unmasked run spends most of its budget on the degenerate high-FA background. The stopping criteria are keyword arguments:

tracks = dti.track_series(
    "ep2d_diff/",
    fa_threshold=0.15,      # stop below this FA
    angle_deg=45.0,         # max turn per step, in DEGREES (converted to a cosine for you)
    step_size=0.5,          # RK4 step, in VOXEL units
    seed_fa_min=0.3,        # only seed where FA is at least this
)

angle_deg is genuinely degrees — the engine takes a cosine internally, and the wrapper converts, so passing 45 cannot silently become "no angular limit".

Write streamlines to DICOM

write_tracts stores the streamlines as a DICOM Tractography Results object. The tracks must be in patient coordinates — exactly what track_series returns:

tracks = dti.track_series("ep2d_diff/")
dti.write_tracts("ep2d_diff/", tracks, "tracts.dcm")

The reference series supplies the demographics and the Frame of Reference UID the coordinates are expressed in, so it should be the series the tracks were computed from. Anatomy and diffusion-model codes default to White Matter and Single Tensor. Omit the output path to get the Part-10 bytes instead of writing a file.

The two guards

Two inputs the engine would accept and quietly mis-fit are refused here instead, because nothing downstream reveals the mistake:

b-vectors must be unit length. The design matrix carries |g|², so a gradient table normalised to anything other than 1 scales every diffusivity by 1/|g|² while leaving FA untouched — invisible to any FA comparison. A non-unit table raises.

baselines are not bvals == 0. UIH writes 1.25 for its b=0 volume and Siemens reports 50 for volumes that are baselines in every other respect, so the split goes through a per-manufacturer threshold. baseline_mask exposes it:

dti.baseline_mask(bvals, manufacturer="SIEMENS")   # True where a volume is a baseline
dti.baseline_mask(bvals, threshold=100.0)           # override the threshold entirely

fit_series reads the Manufacturer off the series for you; pass threshold= if a series encodes its baseline unusually.

Working from arrays

If you already hold a 4-D stack — for instance from pydcm.load_dwi, which returns (volumes, bvals, bvecs, affine)fit and track take it directly. They accept either the (3, V) gradient layout load_dwi hands out or (V, 3), handle the baseline split, and carry an affine into the result:

volumes, bvals, bvecs, affine = pydcm.load_dwi("ep2d_diff/")
res = dti.fit(volumes, bvals, bvecs, maps=("FA", "MD"), affine=affine, mask=True)
tracks = dti.track(volumes, bvals, bvecs, affine=affine)   # patient mm by default

Scope

Single-tensor estimation (FA / MD / AD / RD / DEC / Westin measures), a head mask, and deterministic RK4 tractography with DICOM Tractography output. For research and engineering use only.